AI-assisted liver volumetry & planning

Liver volumetry.
Reimagined.

RADVANTA brings AI-assisted CT liver volumetry, Couinaud segmentation, editable anatomy, 3D visualization and PDF reporting into one workspace. The clinician stays in control.

Controlled beta · Built by a radiologist in India

Ivory liver sculpture in an anterior oblique view, with a broad right lobe and tapered left lobe.
ANATOMY. VOLUMES. CLINICIAN CONTROL.Conceptual liver artwork

Designed around
clinical perspectives

Abdominal radiologyHPB surgeryLiver transplantation

A connected way to work

The whole picture.
Down to the detail.

A liver volume is only useful when you can understand, review and trust the anatomy behind it.

See anatomy in context.

Move between axial, coronal and sagittal CT, segment overlays and 3D anatomy while reviewing the same study.

Make the result yours.

Start with an AI proposal. Refine the segmentation, inspect the measurements and decide what is ready to verify.

Keep the review connected.

Save working drafts, preserve a verified revision and generate a report that refers back to the reviewed result.

See RADVANTA in action

A closer look.
From anatomy to report.

Watch a walkthrough of the RADVANTA workspace, with CT overlays, interactive 3D, planning views and reporting.

Product walkthrough · 1 min 29 secDevelopment preview. Some planning views are in development; case measurements are illustrative.
What the walkthrough shows

The video presents AI-assisted liver and tumor proposals over multiplanar CT, clinician-controlled segmentation editing, interactive 3D anatomy, volume and remnant-selection controls, and a structured report preview. Planning-specific views shown in this development recording do not establish released availability or clinical validation. See “Now & next” for current product status.

See current and planned capabilities

The RADVANTA workspace

The anatomy.
The volumes.
All in view.

One dedicated workspace for the details that matter. Explore a view of the RADVANTA beta below.

Beta interface · Research case example · Displayed values are case-specific, not performance claims.

Read the scan. Review the segmentation.

Axial, sagittal and coronal views bring the source CT and segmentation overlays together, so every boundary can be assessed in context.

Explore the complete toolkit

RADVANTA beta workspace

Full RADVANTA beta workspace screenshot, with CT views, segmented liver in 3D and general volumetry measurements.

Research case example. The screenshot is a product view; this website does not process medical images.

Inside RADVANTA

Every tool.
A clear purpose.

Explore the current beta, from the first segmentation proposal to the verified volumetry report.

AI-assisted anatomy Current beta

A starting point you can inspect.

Generate an anatomical proposal, then review the structures in the context of the original CT.

Liver & Couinaud anatomy

AI-assisted liver and Couinaud segmentation with individually reviewable structure overlays.

Organized structure layers

Anatomy, lesions, Couinaud segments and vessel layers keep different parts of the review organized.

Structure-level control

Add or rename structures, change colors, lock layers and adjust visibility.

Preserved AI proposal

Keep the original proposal available and reset working edits back to that starting point.

Lesion and vessel layers can be reviewed and edited. Automated detection and fine vessel separation are not guaranteed for every structure or case.

The workflow

From CT.
To a reviewed result.

A clear path from the first AI proposal to the result you choose to preserve.

  1. 01

    Open the CT

    Choose a ready study and open the dedicated liver workspace.

  2. 02

    Generate a proposal

    AI provides the starting anatomy for liver and Couinaud review.

  3. 03

    Review & refine

    Inspect CT, overlays and 3D. Correct the anatomy with manual and smart tools.

  4. 04

    Measure & verify

    Review volumes, save a draft and verify the final revision.

  5. 05

    Share the result

    Generate a PDF volumetry report linked to the reviewed revision.

Review first. Verify when ready. Reopen the same saved result.

Now & next

A focused foundation.
A bigger planning vision.

We’re building depth in liver planning, with a clear distinction between the working beta and what comes next.

Current beta

Understand the anatomy.
Review the volumes.

  • AI-assisted anatomy & Couinaud review
  • MPR, 3D & editable segmentation
  • General liver & segment volumetry
  • Durable drafts, verification & PDF reports
Explore the beta features
In development

From volumetry
to virtual planning.

  • Virtual resection & resection-specific FLR
  • Portal & hepatic vein separation
  • Arterial anatomy & vessel-aware planning
  • Donor / graft planning workflows

Research and development priorities. Availability and clinical performance are not yet established.

The thinking behind RADVANTA

Built in India.
Shaped by clinical practice.

Created by Dr Abbu J, a radiologist, RADVANTA starts with a practical belief: clinicians should be able to see how a result was produced, correct it and return to exactly what they reviewed.

A focused product for radiologists, HPB surgeons and transplant teams.

A few useful answers

Before you
take a closer look.

About the controlled beta
What can RADVANTA do today?

The current beta brings AI-assisted liver and Couinaud anatomy, synchronized multiplanar CT review, 3D visualization, segmentation editing, general volumetry, saved drafts, verified revisions and PDF reporting into one workspace. Individual AI-generated structures need clinician review.

Can I correct the AI segmentation?

Yes. The clinician can edit the initial proposal using brush and eraser tools, circle and rectangle scissors, island cleanup, hole filling, smoothing and grow/shrink operations. Smart refinement provides a preview before applying a change. Undo and redo remain part of the review workflow.

Does it calculate future liver remnant or plan a resection?

The current focus is general volumetry of reviewed anatomy. Virtual resection, resection-specific future liver remnant analysis and donor/graft planning are development priorities. They are not presented as released beta capabilities or as tools for determining surgical suitability.

What happens to a reviewed result?

Work can be saved as a draft and reopened. Verification preserves a durable, locked revision of the reviewed anatomy. The volumetry PDF identifies the revision used, helping keep the reported result connected to the reviewed segmentation.

Is RADVANTA ready for routine clinical decisions?

RADVANTA is in controlled beta and is being prepared for evaluation using deidentified retrospective CT studies. It is not presented as an independently validated or regulator-approved clinical device. Segmentation and measurements require clinician review; volumes alone do not establish liver function or surgical suitability.

How can I discuss beta access, pricing or hospital integration?

Email abburadiologyjdh@gmail.com to discuss evaluation interest, pricing or deployment requirements. Public pricing has not been announced, and beta access is arranged separately. Hospital PACS integration and data-handling requirements need institution-specific review.

Where can I see a demo or contact the founder?

Watch the product walkthrough, then contact Dr Abbu J at abburadiologyjdh@gmail.com for product discussions, clinical evaluation or collaboration. You can also use the contact section to copy the email address.

Let’s talk

Have a question?
Reach out directly.

For product discussions, clinical evaluation and collaboration, contact Dr Abbu J.

Tap the address to open your email app, or copy it to use elsewhere.

For initial enquiries, please share your interest and institution without patient-identifying information.

Controlled evaluation

Help shape the
next step in liver planning.

Preparing for evaluation with abdominal radiologists, HPB surgeons and transplant teams, beginning with deidentified retrospective CT studies.

Discuss beta evaluation

Contact us to express interest. No patient uploads on this website.